Keresés

Új hozzászólás Aktív témák

  • csixy

    addikt

    válasz Frawly #64286 üzenetére

    [senki@fatengelyes-pc ~]$ sudo smartctl -t short /dev/sdb
    [sudo] senki jelszava:
    smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.8-arch1-1-ARCH] (local build)
    Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

    === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
    Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
    Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
    Testing has begun.
    [senki@fatengelyes-pc ~]$ sudo smartctl -t short -a /dev/sdb
    smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.8-arch1-1-ARCH] (local build)
    Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

    === START OF INFORMATION SECTION ===
    Model Family: Indilinx Barefoot based SSDs
    Device Model: Corsair CSSD-V32GB2
    Serial Number: 10340061080009870002
    Firmware Version: 2.1
    User Capacity: 32.017.047.552 bytes [32,0 GB]
    Sector Size: 512 bytes logical/physical
    Rotation Rate: Solid State Device
    Device is: In smartctl database [for details use: -P show]
    ATA Version is: ATA8-ACS (minor revision not indicated)
    Local Time is: Sun Dec 16 20:51:54 2018 CET
    SMART support is: Available - device has SMART capability.
    SMART support is: Enabled

    === START OF READ SMART DATA SECTION ===
    SMART Status not supported: Incomplete response, ATA output registers missing
    SMART overall-health self-assessment test result: PASSED
    Warning: This result is based on an Attribute check.

    General SMART Values:
    Offline data collection status: (0x00) Offline data collection activity
    was never started.
    Auto Offline Data Collection: Disabled.
    Self-test execution status: ( 249) Self-test routine in progress...
    90% of test remaining.
    Total time to complete Offline
    data collection: ( 0) seconds.
    Offline data collection
    capabilities: (0x1d) SMART execute Offline immediate.
    No Auto Offline data collection support.
    Abort Offline collection upon new
    command.
    Offline surface scan supported.
    Self-test supported.
    No Conveyance Self-test supported.
    No Selective Self-test supported.
    SMART capabilities: (0x0003) Saves SMART data before entering
    power-saving mode.
    Supports SMART auto save timer.
    Error logging capability: (0x00) Error logging NOT supported.
    General Purpose Logging supported.
    Short self-test routine
    recommended polling time: ( 0) minutes.
    Extended self-test routine
    recommended polling time: ( 0) minutes.

    SMART Attributes Data Structure revision number: 16
    Vendor Specific SMART Attributes with Thresholds:
    ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
    1 Raw_Read_Error_Rate 0x0000 --- --- --- Old_age Offline - 6
    9 Power_On_Hours 0x0000 --- --- --- Old_age Offline - 490
    12 Power_Cycle_Count 0x0000 --- --- --- Old_age Offline - 807
    184 Initial_Bad_Block_Count 0x0000 --- --- --- Old_age Offline - 11
    195 Program_Failure_Blk_Ct 0x0000 --- --- --- Old_age Offline - 0
    196 Erase_Failure_Blk_Ct 0x0000 --- --- --- Old_age Offline - 0
    197 Read_Failure_Blk_Ct 0x0000 --- --- --- Old_age Offline - 0
    198 Read_Sectors_Tot_Ct 0x0000 --- --- --- Old_age Offline - 4239321810
    199 Write_Sectors_Tot_Ct 0x0000 --- --- --- Old_age Offline - 2198158606
    200 Read_Commands_Tot_Ct 0x0000 --- --- --- Old_age Offline - 90344251
    201 Write_Commands_Tot_Ct 0x0000 --- --- --- Old_age Offline - 38618593
    202 Error_Bits_Flash_Tot_Ct 0x0000 --- --- --- Old_age Offline - 11514890
    203 Corr_Read_Errors_Tot_Ct 0x0000 --- --- --- Old_age Offline - 10661672
    204 Bad_Block_Full_Flag 0x0000 --- --- --- Old_age Offline - 0
    205 Max_PE_Count_Spec 0x0000 --- --- --- Old_age Offline - 5000
    206 Min_Erase_Count 0x0000 --- --- --- Old_age Offline - 533
    207 Max_Erase_Count 0x0000 --- --- --- Old_age Offline - 1156
    208 Average_Erase_Count 0x0000 --- --- --- Old_age Offline - 899
    209 Remaining_Lifetime_Perc 0x0000 --- --- --- Old_age Offline - 83
    211 SATA_Error_Ct_CRC 0x0000 --- --- --- Old_age Offline - 0
    212 SATA_Error_Ct_Handshake 0x0000 --- --- --- Old_age Offline - 0
    213 Indilinx_Internal 0x0000 --- --- --- Old_age Offline - 0

    Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
    SMART Error Log Version: 1
    No Errors Logged

    Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
    SMART Self-test log structure revision number 1
    No self-tests have been logged. [To run self-tests, use: smartctl -t]

    Selective Self-tests/Logging not supported

    === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
    Can't start self-test without aborting current test (90% remaining),
    add '-t force' option to override, or run 'smartctl -X' to abort test.
    [senki@fatengelyes-pc ~]$

Új hozzászólás Aktív témák